Data Center Battery Backup System Bespoke Service

The Gerchamp 8XNFZ38 nickel-zinc data center battery backup system provides a lightweight, highly safe, and environmentally friendly backup solution for key facilities by virtue of the non-fire characteristics of 3C high-rate discharge and UL9540A certification.

Data center battery backup system

Cloud Computing Center Infrastructure Directors

Suitable for O&M teams responsible for hyperscale centers to solve space constraints and load-bearing problems.

Data center battery backup system applicable group

Financial Bank Core Room Administrators

Ideal for bank settlement centers with high fire protection requirements, providing a physical-level safety barrier for core transaction data.

Data center battery backup system applicable group

Telecom Base Station and Edge Computing Operations

Provides maintenance-free and easy-to-recover green energy solutions for widely distributed edge nodes.

Data center battery backup system applicable group

Petrochemical Systems Assurance Teams

The UL9540A certified fire-free feature improves the reliability of emergency power systems in safety-sensitive industrial environments.

Data center battery backup system applicable group
Data center battery backup system(images 6)

Triple High-Current High-Rate Discharge

Support continuous discharge at the highest 3C rate, meeting the instantaneous high-power output requirements of the data center, significantly reducing the number of parallel battery packs and saving installation space.

Data center battery backup system(images 7)

Intrinsically Safe, No Fire and No Explosion

Through the UL9540A extreme thermal runaway test, there is no circuit failure during discharge, no explosion or fire risk, and the safety is significantly better than traditional lead-acid and lithium battery solutions.

Data center battery backup system(images 8)

High-Density Lightweight Structure Design

With a gravimetric energy density of 67.7 Wh/kg and a total weight of only 7.8kg (±200g), this system greatly reduces the floor load of high-rise machine rooms.

Data center battery backup system(images 9)

Excellent Wide Temperature Range Adaptability

Supports stable operation in the range of -20°C to 55°C, ensuring that the backup power supply can still respond reliably in extreme environments.

Data center battery backup system(images 10)

High-Efficiency 1C Fast Power-Up Technology

With 1C fast charging rate, the standby power-up time after power interruption is greatly shortened, ensuring the system is ready at any time for consecutive failures.

Data center battery backup system(images 11)

Environmental Compliance Green Material System

The use of V0-grade flame-retardant ABS engineering materials and no heavy metal pollution, in line with RoHS directives and EU regulations, helps enterprises achieve green data center construction standards.

Technical Parameters8XNFZ38 Detailed Specifications
Rated Voltage13.2V (8 x 1.65V batteries)
Nominal Capacity38Ah (1C discharge to 10.4V)
Nominal Power920W (30-minute frequency)
Product Weight7,800 ± 200g
Volumetric Energy Density137.4 Wh/L
Internal Resistance< 8mΩ
Fast Charging Speed1C (10°C to 45°C)
Maximum Discharge Rate3C (-10°C to 55°C)
Shell Material GradeV0 flame-retardant ABS
Authoritative CertificationUL9540A, RoHS, TTL

The battery backup system of Gerchamp data center adopts an advanced nickel-zinc chemical system. Its volumetric energy density of 137.4 Wh/L is far higher than that of traditional lead-acid batteries, significantly improving the power backup efficiency per unit area of the computer room.

Data center battery backup system

Data center battery backup system(images 13)

Eliminate the hidden danger of excessive load-bearing in high-rise computer rooms

Gerchamp solves the problem of requiring additional reinforced floors due to the excessive weight of traditional batteries. The lightweight design makes backup system deployment more flexible and efficient.

Data center battery backup system(images 14)

Solve the power supply delay after frequent power outages

For the industry pain point of slow backup power recharge, Gerchamp supports 1C fast charging technology, allowing the system to re-enter full-power readiness in a very short time.
Data center battery backup system(images 15)

Avoid the fire caused by the battery thermal runaway

Addressing the inherent thermal runaway risks of lithium systems, Gerchamp ensures the continuous and stable operation of financial and data businesses through non-fire physical characteristics.
Q: What is the maximum discharge rate of the 8XNFZ38 battery?
A: This model supports a maximum 3C discharge rate and provides instantaneous high power output in environments from -10°C to 55°C.
Q: Will this battery explode under extreme damage?
A: No. The product has passed extreme destructive testing with no risk of explosion or fire, making it safer than current mainstream alternatives.
Q: How does the 8XNFZ38 optimize the footprint of a data center?
A: Due to its high energy density and 3C high-rate discharge capability, the system requires fewer parallel battery strings compared to lead-acid solutions. This allows facility managers to reclaim valuable floor space or increase backup capacity within the same footprint.
Q: How does the charging efficiency of the system perform?
A: It supports 1C fast charging, which can complete power replenishment in a very short time and significantly improve the emergency response frequency of the system.
Q: What is the self-discharge situation when not in use for a long time?
A: After 12 months of storage, its capacity retention rate remains at ≥ 70%, showing excellent charge retention performance.
Q: Does the shell material have fire protection function?
A: Yes, the shell adopts V0-grade flame-retardant ABS engineering material, meeting the highest level of industrial fire safety standards.
E-mail*
Number
Country
Name
Your Question
Submitting!
Success!
Submission failed! Please try again later!
Email format error!
Format error!

Data Center Battery Backup System Bespoke Service

The Gerchamp 8XNFZ38 nickel-zinc data center battery backup system provides a lightweight, highly safe, and environmentally friendly backup solution for key facilities by virtue of the non-fire characteristics of 3C high-rate discharge and UL9540A certification.

Data center battery backup system

Data center battery backup system(images 17)

Support continuous discharge at the highest 3C rate, meeting the instantaneous high-power output requirements of the data center, significantly reducing the number of parallel battery packs and saving installation space.

Data center battery backup system(images 18)

Through the UL9540A extreme thermal runaway test, there is no circuit failure during discharge, no explosion or fire risk, and the safety is significantly better than traditional lead-acid and lithium battery solutions.

Data center battery backup system(images 19)

With a gravimetric energy density of 67.7 Wh/kg and a total weight of only 7.8kg (±200g), this system greatly reduces the floor load of high-rise machine rooms.

Data center battery backup system(images 20)

Supports stable operation in the range of -20°C to 55°C, ensuring that the backup power supply can still respond reliably in extreme environments.

Data center battery backup system(images 21)

With 1C fast charging rate, the standby power-up time after power interruption is greatly shortened, ensuring the system is ready at any time for consecutive failures.

Data center battery backup system(images 22)

The use of V0-grade flame-retardant ABS engineering materials and no heavy metal pollution, in line with RoHS directives and EU regulations, helps enterprises achieve green data center construction standards.

Technical Parameters8XNFZ38 Detailed Specifications
Rated Voltage13.2V (8 x 1.65V batteries)
Nominal Capacity38Ah (1C discharge to 10.4V)
Nominal Power920W (30-minute frequency)
Product Weight7,800 ± 200g
Volumetric Energy Density137.4 Wh/L
Internal Resistance< 8mΩ
Fast Charging Speed1C (10°C to 45°C)
Maximum Discharge Rate3C (-10°C to 55°C)
Shell Material GradeV0 flame-retardant ABS
Authoritative CertificationUL9540A, RoHS, TTL

Data center battery backup system

Data center battery backup system(images 24)
Gerchamp solves the problem of requiring additional reinforced floors due to the excessive weight of traditional batteries. The lightweight design makes backup system deployment more flexible and efficient.
Data center battery backup system(images 25)
For the industry pain point of slow backup power recharge, Gerchamp supports 1C fast charging technology, allowing the system to re-enter full-power readiness in a very short time.
Data center battery backup system(images 26)
Addressing the inherent thermal runaway risks of lithium systems, Gerchamp ensures the continuous and stable operation of financial and data businesses through non-fire physical characteristics.

Cloud Computing Center Infrastructure Directors

Suitable for O&M teams responsible for hyperscale centers to solve space constraints and load-bearing problems.

Data center battery backup system applicable group

Financial Bank Core Room Administrators

Ideal for bank settlement centers with high fire protection requirements, providing a physical-level safety barrier for core transaction data.

Data center battery backup system applicable group

Telecom Base Station and Edge Computing Operations

Provides maintenance-free and easy-to-recover green energy solutions for widely distributed edge nodes.

Data center battery backup system applicable group

Petrochemical Systems Assurance Teams

The UL9540A certified fire-free feature improves the reliability of emergency power systems in safety-sensitive industrial environments.

Data center battery backup system applicable group
Q: What is the maximum discharge rate of the 8XNFZ38 battery?
A: This model supports a maximum 3C discharge rate and provides instantaneous high power output in environments from -10°C to 55°C.
Q: Will this battery explode under extreme damage?
A: No. The product has passed extreme destructive testing with no risk of explosion or fire, making it safer than current mainstream alternatives.
Q: How does the 8XNFZ38 optimize the footprint of a data center?
A: Due to its high energy density and 3C high-rate discharge capability, the system requires fewer parallel battery strings compared to lead-acid solutions. This allows facility managers to reclaim valuable floor space or increase backup capacity within the same footprint.
Q: How does the charging efficiency of the system perform?
A: It supports 1C fast charging, which can complete power replenishment in a very short time and significantly improve the emergency response frequency of the system.
Q: What is the self-discharge situation when not in use for a long time?
A: After 12 months of storage, its capacity retention rate remains at ≥ 70%, showing excellent charge retention performance.
Q: Does the shell material have fire protection function?
A: Yes, the shell adopts V0-grade flame-retardant ABS engineering material, meeting the highest level of industrial fire safety standards.
*
Submitting!
Success!
Submission failed! Please try again later!
Email format error!
Format error!